Description
The Pancake Load Cell is a Low Profile Tension & Compression Load Cell – 5kN to 1000kN.
Options:
• Other ranges available on request
• Full range of mounting options
• Connector version
• Double bridge version
• Atex approved version
Dynamic Load Monitoring’s Pancake Load Cells can be custom-designed by our in-house design team, who will be able to provide solutions to your specific product requirements.
Key features
- Range 5kN to 1000kN
- Low profile design
- Low deflection
- Atex certification available
- High natural frequency
- Excellent rejection of extraneous forces
- Fatigue rated to 109 full cycles
Applications
- Test machines
- Cable engines and tensioners
- Offshore applications
- Integration in OEM applications
Dimensional data
Range (kN) | Part Number | ØD | H | ØG | ØK | T |
---|---|---|---|---|---|---|
5 | 0001 – 1098 | 107 | 33 | 90 | 8 off Ø8.5 | M20x2 |
10 | 0001 – 1099 | 107 | 33 | 90 | 8 off Ø8.5 | M20x2 |
25 | 0001 – 1100 | 107 | 33 | 90 | 8 off Ø8.5 | M20x2 |
50 | 0001 – 1101 | 107 | 33 | 90 | 8 off Ø8.5 | M20x2 |
100 | 0001 – 1102 | 155 | 45 | 130 | 12 off Ø11 | M36x2 |
200 | 0001 – 1103 | 155 | 45 | 130 | 12 off Ø11 | M36x2 |
500 | 0001 – 1104 | 280 | 78 | 230 | 16 off Ø17 | M64x6 |
1000 | 0001 – 1105 | 280 | 78 | 230 | 16 off Ø17 | M64x6 |
Product specification
Capacities | ±5, ±10, ±25, ±50, ±100, ±200, ±500, ±1000 kN |
Full Load Output | 2.0 (±0.25%) mV/V |
Zero Load Output | <±2.0 % |
Excitation (Max) | 10 (15) V |
Accuracy | <0.1 % |
Repeatability | <0.03 % |
Input Resistance | 375 (±20) Ω |
Output Resistance | 350 Ω |
Compensated Temp. Range | -10 to +40 °C |
Operating Temp. Range | -20 to +60 °C |
Temp. Coefficient on Zero | <0.005% Capacity/°C |
Safe Overload | 150 % |
Insulation | 500MΩ @100Vdc |
Environmental Protection | IP65 |
Cable Length | 4m |